Fire-Rated Door Services for
Bay Area Buildings

A fire door is a tested assembly. The door, frame and every piece of hardware have to match the listing, or the rating is gone.

Fire Door Installation

New fire-rated assemblies in hollow metal and wood. Door, labeled frame, listed hinges, closer and latch installed together to the listing.

Get a quote

Fire Door Repair

Doors that won't close, won't latch or drag on the frame. We fix the cause with listed parts so the opening keeps its rating.

Get a quote

Fire Door Replacement

When a label is missing, painted over or the door is damaged beyond repair, we replace the assembly with one that carries the right rating.

Get a quote

Closers & Hinges

Self-closing is required on every fire door. We replace failing closers and worn hinges and tune them so the door closes and latches from any angle.

Get a quote

Fire Exit Hardware

Panic devices on fire doors need a fire exit hardware listing. We install and repair rim, mortise and vertical rod devices that carry it.

Get a quote

Smoke Seals & Gasketing

Smoke-rated openings need listed gasketing. We install and replace seals and correct gaps that let smoke through.

Get a quote

What Makes a Fire Door Pass Inspection?

A fire door passes when it carries the right rating for its wall, closes on its own and latches every time. These are the basics we check on every job.

Common fire door ratings

The wall decides the door. A higher-rated wall needs a higher-rated door.

Door ratingTypical location
20 minutesCorridor doors and smoke partitions
45 minutes1-hour fire barriers, such as room separations
60 minutes1-hour stairwells and shafts
90 minutes2-hour walls, stairwells and shafts
3 hours3-hour fire walls and barriers

Based on the International Building Code. Your building plans or the local fire marshal set the exact rating for each opening.

What inspectors check

  • Labels. The door and the frame each carry a legible fire label. Paint over it and the rating can't be verified.
  • Self-closing. The door closes fully on its own from any open position.
  • Positive latching. The latch bolt engages the strike and holds the door shut.
  • Listed hardware. Hinges, closer, latch and exit device are all listed for fire doors.
  • Tight clearances. About 1/8 inch at the jambs and head on steel doors, and no more than 3/4 inch at the bottom in most cases.
  • Nothing holding it open. No wedges, kick-down stops or chains.

Trusted by Bay Area Businesses

★★★★★ 4.89 · Google Reviews · 66 ratings
★★★★★

"Gilmore Doors & Hardware did an excellent job installing doors for our business in Campbell. Their team was professional, efficient, and detail-oriented from start to finish."

BC
Business Client
Campbell, CA
★★★★★

"We had a great experience working with Anthony from Gilmore Doors & Hardware. He was incredibly easy to work with and clearly knows his craft."

DL
Doug Levitt
Burlingame, CA
★★★★★

"Anthony is my go-to person for any door work. He's done a couple of jobs for both me and my friends, and every time he's delivered outstanding results."

TN
Trung Nguyen
San Mateo, CA

Most Fire Doors Fail on
Small, Fixable Things.

A fire door can look fine and still fail. One swapped part or a gap that grew over time is enough. NFPA 80 requires every fire door assembly to be inspected and tested once a year, so small problems surface fast.

The good news is most failures are repairs, not replacements. We find the cause and fix it with parts that keep the listing.

Annual Fire door inspection required under NFPA 80
1/8″ Typical max gap at jambs and head, steel doors
3/4″ Typical max clearance at the bottom of the door
3 Minimum hinges on a door up to 7 feet tall

The Four Fire Door Failures We Fix Most

Door Propped or Held Open

Wedges and kick-down stops are the most cited fire door violation. If the door has to stay open, it needs a listed hold-open tied to the alarm.

Closes but Doesn't Latch

A weak closer, sagging hinges or a shifted strike stops the latch from catching. The door looks shut but fails the test.

Non-Listed Hardware

A lever or closer from the hardware store can void the rating. Every part on the door has to be listed for fire doors.

Painted Labels and Big Gaps

A painted-over label or gaps that grew past tolerance mean the door can't be verified. Some fix with adjustment, others need a new assembly.

Fire Door Service from San Francisco to San Jose

Two Bay Area locations in Menlo Park and Campbell. Commercial jobs covered across the Peninsula, South Bay and San Francisco.

Where We Install and Repair Fire Doors

Based in Menlo Park with a second location in Campbell. We travel to San Francisco for commercial work.

  • San Francisco
  • South San Francisco
  • San Mateo
  • Redwood City
  • Menlo Park
  • Palo Alto
  • Mountain View
  • Sunnyvale
  • Santa Clara
  • San Jose
  • Campbell
  • Los Gatos
Request a Fire Door Estimate

Fire Door FAQ

Answers to the questions property managers and facility teams ask us most.

It depends on what failed. Replacing a closer, hinges or latch is far cheaper than replacing the door or frame. We inspect the opening and give you a free itemized estimate before any work starts.
Most fire doors can be repaired. Closers, hinges, latches and seals can be replaced with listed parts without voiding the rating. Replacement is needed when the label is missing or painted over, or when the door or frame has holes, warping or damage that breaks the fire barrier.
Every year. NFPA 80 requires annual inspection and testing of every fire door assembly, and the building owner has to keep the records for the fire marshal.
No. Wedges, kick-down stops and chains are not allowed on fire doors. If a door has to stay open during the day, it needs a listed electromagnetic hold-open tied to the fire alarm, so it releases and closes when the alarm goes off.
No, it should be a licensed door contractor who knows the listings. Wrong hardware, oversized gaps or regular spray foam behind the frame can void the rating, and the door fails inspection even if it looks fine.
It depends on the wall it sits in. A 2-hour wall usually needs a 90-minute door, and corridor doors often need 20 minutes. Your plans or the fire marshal set the exact rating, and we match the door, frame and hardware to it.

Fire Door Failed Inspection
or Won't Latch?

We install, repair and replace fire-rated doors from San Francisco to San Jose. Free itemized estimates.